Rosemount 9930 Magnetic Level Indicator

Part number9930ManufacturerEmerson

Purchase options

Request a quote

Availability
Call for availability Originalx
Request Price

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Magnetic level indicator with a dry flag column and a float selected by SG and pressure: no process fluid at the glass, -162 to 454 C, to 3400 psig.

Key features

  • Magnetic level indicator: a chamber, a magnet-equipped float and a column of flip flags, with red showing the liquid level and silver the vapor space
  • No process liquid contacts the indicator glass, because the indicator is a dry column of flags moved by a magnetic field through the chamber wall rather than a window into the process - which is why minimal leak points and sight glass replacement are on the benefit list
  • The float table is a trade curve: as minimum SG rises from 0.58 to 0.86 the float's pressure limit rises from 94 to 948 psig, because a float that floats in a light liquid needs thin walls and displacement while a float that holds pressure needs thick walls and therefore weight
  • Titanium floats reach the lightest service at 0.54 SG. The floor is 0.40 SG below which the factory must be consulted, and float pressure rating reaches 3400 psig at 100 F
  • Interface measurement requires a minimum delta SG of 0.11, so two similar hydrocarbon fractions or a diluted aqueous layer cannot be resolved - the float sits where buoyancy favours and the indication becomes an average
  • Temperature range -260 to 850 F (-162 to 454 C) with the chamber to ASME B31.3 and NACE construction on request, hydrostatically tested to 1.5 times MAWP. The same float can drive external magnetostrictive transmitters and magnetic switches with no second process penetration, and a dual chamber version gives a guided wave radar a calm stilling column in a turbulent vessel

Key specifications

Accuracy
Resolution is set by the flag pitch, and the reading is the float position rather than a computed value. The selection constraint is the float: it must float in the process liquid and survive the process pressure, and those two requirements pull opposite ways
Output signal
Local flag column, red for liquid and silver for vapour. The same float drives externally mounted magnetostrictive transmitters and magnetic switches through the chamber wall, so a vessel can have local indication, a 4-20 mA signal and alarm contacts with no second process penetration
Diagnostics
The float table is a trade curve and reading it correctly is the whole specification: as minimum SG rises from 0.58 to 0.86 the float's pressure limit rises from 94 to 948 psig, because a float that floats in a light liquid needs thin walls and large displacement while one that holds pressure needs thick walls and therefore weight. A float chosen for 0.86 SG in a liquid that actually sits at 0.7 does not float, and the failure is silent - the flags simply stop where they stopped
Pressure range
Float pressure rating up to 3400 psig (234.4 bar) at 100 F, with the float's own limit set by its selection: 94 psig for the 0.58 SG float up to 948 psig for the 0.86 SG float. The chamber is designed to ASME B31.3 and can be hydrostatically tested to 1.5 times the MAWP of its flange or pressure rating before shipment, with certificates available
Application
Turbulent tanks, heat exchangers, boilers, separators, acid storage and any vessel where a sight glass is being replaced because it is a leak point, a fouling surface or a hazard. A local level that reads without power is the quiet advantage of a mechanical indication
Mounting
Chamber with process connections, vent and drain, mounted beside the vessel. A dual chamber version is built for use with the Rosemount 5300, 3308 and 3300 guided wave radars, so the radar measures inside a calm stilling column instead of the open vessel - which is how a radar gets a stable surface on a turbulent, boiling or agitated tank
See all specifications