Skip to main content
Sold and shipped by Sproh

Rosemount 9935 Level Bypass Chamber

Part number9935ManufacturerEmerson

Purchase options

Request a quote

Availability
Call for availability Originalx
Request Price

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

Level bypass chamber for external mounting of radars and switches: Class 2500, ASME B31.3, live instrument maintenance and a stilling well.

Key features

  • Level bypass chamber (bridle) for externally mounting level instruments on a vessel, rated to ASME B16.5 Class 2500 and designed to ASME B31.3 with B31.1 available
  • The instrument moves off the vessel, so it can be isolated and serviced live while the process keeps running - the difference between a radar on a nozzle and a radar on a chamber with two isolating connections
  • A chamber gets bought for one of three separate reasons: in-tank constraints such as an agitator or heat exchanger bundle, isolation for live maintenance and hazardous liquids, or turbulence where the chamber acts as a stilling well
  • Once the instrument is on the chamber it measures the chamber, not the vessel: a blocked lower connection traps liquid and freezes the reading, and a blocked upper connection disconnects the vapour space so the indicated level drifts with temperature
  • Drain and optional vent exist so the column can be emptied, flushed and refilled deliberately rather than by hope, and both belong in the commissioning procedure and the periodic check
  • Weld neck flanges throughout and all welds full penetration, specified to reduce stress and crevice corrosion - the failure mode that matters in a small pressure boundary nobody inspects inside

Key specifications

Accuracy
Not a measuring device. It is the enclosure that makes a level measurement possible, and its success is measured in whether the instrument beside it can be trusted and reached. Once the instrument is on the chamber it measures the chamber, not the vessel, so the chamber's own connections become part of the measurement
Output signal
Not applicable - a passive pressure component with process connections, a drain and an optional vent. It accepts Rosemount guided wave radar, non-contacting radar and vertical level switches mounted on its top flange or side connections
Diagnostics
Two failure modes belong to the installation rather than the instrument: a blocked lower connection traps liquid in the chamber and freezes the reading at whatever it was last equal to, which is not obviously a fault on an undisturbed vessel; a blocked upper connection disconnects the vapour space, so the pressure above the chamber liquid is no longer the vessel's and the indicated level drifts with temperature. The drain and optional vent exist so the column can be emptied, flushed and refilled deliberately, and both belong in commissioning and in the periodic check
Pressure range
Rated for pressures up to ASME B16.5 Class 2500. Weld neck flanges are used throughout to reduce stress concentration, and all welds are full penetration, which the datasheet specifies for integrity and to reduce crevice corrosion - the failure mode that matters in a small pressure boundary nobody inspects from inside
Application
Externally mounting a level instrument on a vessel: distillation columns and reactors where a guided wave radar needs a clear path or needs to be removable, horizontal tanks with no room for a top-mounted instrument, vessels with agitators or internal heat exchangers, and any service where the instrument must be serviceable without a shutdown
Mounting
Vertical column beside the vessel with two side process connections at different elevations, one top connection for the instrument, and a bottom drain. A custom design service covers nozzle spacing, flange rating and code requirements, because a bridle is frequently a made-to-order pressure component
See all specifications