Resumen

Camara de derivacion de nivel para montar radares e interruptores externamente: Clase 2500, ASME B31.3, mantenimiento en vivo del instrumento y pozo de amortiguacion.

Especificaciones principales

Exactitud
Not a measuring device. It is the enclosure that makes a level measurement possible, and its success is measured in whether the instrument beside it can be trusted and reached. Once the instrument is on the chamber it measures the chamber, not the vessel, so the chamber's own connections become part of the measurement
Señal de salida
Not applicable - a passive pressure component with process connections, a drain and an optional vent. It accepts Rosemount guided wave radar, non-contacting radar and vertical level switches mounted on its top flange or side connections
Diagnósticos
Two failure modes belong to the installation rather than the instrument: a blocked lower connection traps liquid in the chamber and freezes the reading at whatever it was last equal to, which is not obviously a fault on an undisturbed vessel; a blocked upper connection disconnects the vapour space, so the pressure above the chamber liquid is no longer the vessel's and the indicated level drifts with temperature. The drain and optional vent exist so the column can be emptied, flushed and refilled deliberately, and both belong in commissioning and in the periodic check
Rango de presión
Rated for pressures up to ASME B16.5 Class 2500. Weld neck flanges are used throughout to reduce stress concentration, and all welds are full penetration, which the datasheet specifies for integrity and to reduce crevice corrosion - the failure mode that matters in a small pressure boundary nobody inspects from inside
Aplicación
Externally mounting a level instrument on a vessel: distillation columns and reactors where a guided wave radar needs a clear path or needs to be removable, horizontal tanks with no room for a top-mounted instrument, vessels with agitators or internal heat exchangers, and any service where the instrument must be serviceable without a shutdown
Montaje
Vertical column beside the vessel with two side process connections at different elevations, one top connection for the instrument, and a bottom drain. A custom design service covers nozzle spacing, flange rating and code requirements, because a bridle is frequently a made-to-order pressure component