Rosemount CX2100 In-Situ Oxygen Analyzer

Part numberCX2100ManufacturerEmerson

Purchase options

From$1,351.79

Availability
Call for availability Originalx
Select option

Configurable — choose options to build the exact part number.

Independent supplier

Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.

Overview

In-situ zirconia oxygen analyzer for flue gas: 0-10 percent O2 factory range to 50 percent, 0.02 percent detection limit, diffuser chosen by duct temperature.

Key features

  • In-situ zirconia oxygen analyzer for furnace and boiler flue gas: factory range 0 to 10 percent O2, user range to 50 percent, detection limit 0.02 percent O2
  • Measuring in the duct removes the extractive sample system entirely, so there is no sample line to plug with ash, no pump to fail, no cooler to flood and no filter to load up while the analyzer keeps reporting a number
  • The diffuser decides probe life and is chosen by temperature: stainless steel snubber to 750 F (400 C), ceramic or Alloy C-276 to 1300 F (704 C)
  • Flame safety interlock powers down the heater when the burner flame is lost, which matters because a hot zirconia cell in a duct carrying unburnt gas is an ignition source
  • Reference air is a consumable the installation has to provide: clean dry instrument air at 20 psi and 2 scfh. If it is wet or contaminated the cell does not stop working, it produces a wrong but plausible reading because the reference has changed
  • Measurement drift is published at three concentrations - 0.05 percent O2 per month at 0.4 percent, 0.1 at 8 percent, 0.25 at 20 percent - so the calibration interval follows the operating point. The SPS 4001B autocalibration system sequences the gases automatically

Key specifications

Accuracy
Repeatability 0.75 percent of reading or 0.05 percent O2, whichever is greater, from 0 to 10 percent; 1 percent of reading above 10 percent. Lowest detection limit 0.02 percent O2. The stoichiometric advanced feature repeats to 0.2 percent across an O2 deficiency of 0 to 2 percent
Output signal
4-20 mA analog output with configurable lower and upper range values (LRV 0 to 49 percent O2, URV 1 to 50 percent O2), local operator interface rotatable in 90 degree steps, and relay or autocalibration output options. Remote electronics in an explosion-proof housing rated ATEX/IECEx Ex db and Class I Division/Zone 1
Diagnostics
Measurement drift is published at three concentrations: 0.05 percent O2 per month at 0.4 percent, 0.1 at 8 percent and 0.25 at 20 percent, so the calibration interval follows the operating point. Reference air must be clean, dry instrument air at 20 psi and 2 scfh - if it is wet or contaminated the cell keeps working and reports a wrong but plausible reading, because the reference itself has changed. The SPS 4001B autocalibration system sequences low and high calibration gases automatically on a timer, relay or manual command
Pressure range
Not applicable in the usual sense - the probe is inserted into a duct at essentially atmospheric pressure. The installation limits are the duct temperature and the probe insertion depth rather than a pressure rating
Application
Excess oxygen in furnace and boiler flue gas for combustion trim, efficiency monitoring and emissions support: process heaters, kilns and incinerators. The probe sits in the duct, which removes the extractive sample system - and with it the sample line that plugs with ash, the pump that fails and the cooler that floods
Operating temperature (°C)
Diffuser limits set the maximum: stainless steel snubber 750 F (400 C), ceramic or Alloy C-276 1300 F (704 C). Selecting a stainless diffuser for a duct above 400 C is not a marginal error, it is a probe that fails early and repeatedly
See all specifications