Rosemount Model 372 pH Sensor
Purchase options
From$730.51
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
HF-resistant pH sensor for fluoride and hydrofluoric acid service: 0 to 12 pH, Ultem body, double junction gel reference, integral Pt-100.
Key features
- pH sensor built for fluoride and hydrofluoric acid service, model 372
- Special glass formulation that reduces HF attack by more than a factor of ten
- 0 to 12 pH (0 to 14 without sodium ions), acidic error below 0.01 pH in 1.0 M HCl
- Double junction reference with saturated KCl in cross-linked polymer, resistant to poisoning ions
- Ultem body, Viton seals, Kynar cable, hemispherical 7.8 mm glass with impedance under 400 MOhm
- 3/4 in. MNPT insertion and 1 in. MNPT submersion connections; integral Pt-100 and preamplifier options
Key specifications
- Accuracy
- Acidic error below 0.01 pH in 1.0 M HCl at pH 0; glass impedance below 400 MOhm at 25 C
- Diagnostics
- Double junction reference with saturated KCl in cross-linked polymer, resistant to poisoning ions and needing no refilling; the glass formulation reduces HF attack by more than a factor of ten
- Pressure range
- -13 to 135 psig (6.9 to 1035 kPa abs)
- Measurement range
- 0 to 12 pH, or 0 to 14 pH when no sodium ions are present (sodium error at high pH is a property of the glass)
- Sensor connection
- 3/4 in. MNPT forward connection for insertion and 1 in. MNPT rear connection for submersion; integral Pt-100 RTD; 25 ft cable with integral preamplifier (01) or 15 ft cable without (02)
- Application
- pH measurement in fluoride and hydrofluoric acid bearing processes: etching solutions, pickling and metal finishing baths, and wastewater where fluoride is present
A pH sensor for the acid that normally eats pH sensors
The Rosemount 372 is built for fluoride-bearing processes — etching baths and wastewater carrying hydrofluoric acid — where an ordinary pH glass bulb dissolves. Its glass formulation is the whole product: Emerson states it reduces HF attack by more than a factor of ten, which is the difference between a sensor that lasts a campaign and one that lasts a fortnight.
Why HF is different from other acids
Hydrofluoric acid attacks the silica network of pH glass directly, dissolving the membrane that produces the measurement potential. A sensor then does not drift; it loses its bulb. The 372's glass resists that attack, and the body around it is Ultem with Viton seals and a Kynar cable jacket, chosen because the same fluoride environment attacks ordinary plastics and elastomers too.
Reference and signal
The reference is a double junction with saturated KCl in a cross-linked polymer — a gel rather than a liquid, so it does not leak out through the junction in a flowing line and does not need refilling. That design also resists poisoning ions, which is the failure mode that makes a reference drift for no visible reason. The glass is hemispherical, 7.8 mm diameter, with impedance below 400 MΩ at 25 °C, and the acidic error is under 0.01 pH in 1.0 M HCl at pH 0 — the figure that says the sensor still reads correctly in strong acid rather than merely surviving it.
Limits that follow the chemistry
Range is 0 to 12 pH, or 0 to 14 pH when no sodium ions are present, because sodium error at high pH is a property of the glass, not a defect. Temperature is -5 to 50 °C with fluoride present and up to 100 °C without it, and pressure runs -13 to 135 psig. Those two conditions are worth reading together: a hot fluoride stream is outside the sensor's envelope, and specifying it there is the mistake this datasheet is designed to prevent.
Fitting it
There is a 3/4 in. MNPT forward connection for insertion and a 1 in. MNPT rear connection for submersion, with an insertion depth of 2.2 to 8.3 in. The integral Pt-100 handles temperature compensation, and two cable versions exist: 25 ft with an integral preamplifier (01) or 15 ft without (02) — the choice follows the distance to the transmitter, because a high-impedance glass electrode needs the preamplifier close to it.
Where it fits
Semiconductor and glass etching lines, metal finishing and pickling baths, and wastewater treatment where fluoride is present — including the neutralisation steps where pH control determines whether fluoride precipitates or leaves in the effluent.
Manufacturer reference: Rosemount 372 HF Resistant pH Sensor Product Data Sheet, LIQ-PDS-372, June 2017, and Quick Start Guide 00825-0100-3372.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Acidic error below 0.01 pH in 1.0 M HCl at pH 0; glass impedance below 400 MOhm at 25 C |
| Diagnostics | Double junction reference with saturated KCl in cross-linked polymer, resistant to poisoning ions and needing no refilling; the glass formulation reduces HF attack by more than a factor of ten |
| Pressure range | -13 to 135 psig (6.9 to 1035 kPa abs) |
| Measurement range | 0 to 12 pH, or 0 to 14 pH when no sodium ions are present (sodium error at high pH is a property of the glass) |
| Sensor connection | 3/4 in. MNPT forward connection for insertion and 1 in. MNPT rear connection for submersion; integral Pt-100 RTD; 25 ft cable with integral preamplifier (01) or 15 ft cable without (02) |
| Application | pH measurement in fluoride and hydrofluoric acid bearing processes: etching solutions, pickling and metal finishing baths, and wastewater where fluoride is present |
| Mounting | Insertion depth 2.2 to 8.3 in. (56 to 211 mm); suitable for insertion or submersion installation; weight 0.4 kg |
| Material of construction | Ultem body, Viton seals, glass and Kynar cable jacket; hemispherical glass 7.8 mm diameter in a protective cage |
| Operating temperature (°C) | -5 to 50 C (23 to 122 F) with fluoride ions present; up to 100 C (212 F) when no fluoride ions are present |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer