Overview
IR3 hydrocarbon flame detector with four bands between 4 and 5 micrometres, up to 45 m on gasoline and 17 m on wood or paper.
Key features
- IR3 flame detector on QuadSense triple infrared technology, with four infrared bands between 4 and 5 micrometres, detecting hydrocarbon fires up to 150 ft (45 m)
- The range is a property of the fuel, not of the detector: gasoline and n-heptane reach 45 m, kerosene and diesel 32 m, and paper or wood only 17 m at the same sensitivity setting
- Discrimination comes from requiring several narrow bands inside the 4 to 5 micrometre CO2 region to agree in ratio, which separates a flame from a bright grey-body source such as a lamp, a welding arc or sunlight
- Typical response under five seconds, with HART communication over the 0-20 mA current and a universal wiring option
- A flame detector cannot be proven by pressing a button: the FS-975-IR simulator projects a flame signature so the installed device can be verified without an open flame
- The cone viewer and cone of view limiter accessories establish and control what the detector actually sees from its mounting position
Key specifications
- Accuracy
- Not a measurement device. The relevant figure is detection distance, which depends on the fuel: 150 ft (45 m) for gasoline and n-heptane, 107 ft (32 m) for JP5, kerosene, diesel, methane and LPG, 100 ft (30 m) for ethanol and methanol, 83 ft (25 m) for polypropylene, and 57 ft (17 m) for paper and wood, at the highest sensitivity setting for a 1 ft2 pan fire
- Output signal
- Analog/HART/RS-485/relays, with HART communication on the 0-20 mA analog current (FSK) for maintenance, configuration changes and asset management. Fault relay normally closed. Universal wiring option for a streamlined ordering process
- Diagnostics
- A flame detector cannot be proven by pressing a button. The FS-975-IR explosion-proof flame simulator projects a flame signature so the installed device can be verified without an open flame; the cone viewer establishes what the detector sees from its mounting position, and the cone of view limiter narrows the field where a flare stack or furnace door sits inside it
- Pressure range
- Not applicable - an optical flame detector with no process connection and no wetted parts
- Application
- Hydrocarbon fire detection in open and semi-open areas: aircraft hangars, fuel loading racks, tank farms, pump and compressor areas, turbine enclosures and chemical process units, where the fire is a pool or a plume rather than a smouldering solid
- Operating temperature (°C)
- Operating -40 to +158 F (-40 to +70 C)
The 45 m range is a property of the fuel, not of the detector
The Rosemount 965 is an IR3 flame detector built on QuadSense triple infrared technology, with four infrared bands between 4 and 5 µm, a typical response of under five seconds, HART communication over the 0–20 mA current, and a stated detection range of 150 ft (45 m).
That last number is the one everybody reads first, and the datasheet's own range table is where it should be read instead — because 45 m is the range for gasoline and n-heptane.
The range table is the specification
| Fuel | Range at highest sensitivity |
|---|---|
| Gasoline, n-heptane | 150 ft (45 m) |
| JP5, kerosene, diesel, methane, LPG, cooking oil, mineral oil | 107 ft (32 m) |
| Ethanol, isopropyl alcohol, methanol, gun powder | 100 ft (30 m) |
| Polypropylene | 83 ft (25 m) |
| Paper, wood | 57 ft (17 m) |
The spread is over two and a half to one, and it runs in the direction that catches people out. The headline figure belongs to the fuels that burn hot, sooty and bright in the infrared — gasoline, heptane. A wood or paper fire is detected at 17 m, not 45 m, which is a third of the published distance.
So a warehouse, a paper store or a hangar specified on “45 m coverage” has been specified on the best case for a fuel that may not be present. The table is not a disclaimer; it is the engineering data, and the layout of the detectors follows it: spacing is set by the fuel actually stored, and the difference between 45 m and 17 m changes how many detectors a building needs by a factor of seven in area coverage.
Why three bands reject a welder but not a fire
False alarms are the failure mode that matters in flame detection, because the consequence is a deluge system discharged into an occupied area, or a detector that has been put in bypass. The IR3 approach addresses it in the spectrum.
A hydrocarbon fire radiates with the characteristic structure of hot CO2, which produces emission in narrow bands inside 4 to 5 µm. A hot object — a lamp filament, a welding arc, a sunlit surface — radiates as a broad continuum across the same region. By measuring several narrow bands and requiring the ratio between them to look like flame rather than like a grey body, the detector can distinguish a fire from something merely hot. Add the flicker of a flame, which is not steady like a lamp, and the discrimination has two independent handles.
That is what "proven false alarm immunity" is doing in the feature list: the detector is not claiming to be blind to hot things, it is claiming to be able to tell them apart. The optical design is also why the accessory range includes a cone of view limiter — in a corner where a flare stack or a furnace door sits inside the field of view, the practical fix is to narrow the field rather than to desensitise the detector.
How it gets tested without lighting a fire
A flame detector cannot be proven by pressing a button. The test has to present an actual flame signature — flicker in the right bands — at a known distance, in a hazardous area, without an open flame.
That is what the flame simulator (FS-975-IR) is for: a handheld source that projects a flame-like signature so the detector's response can be verified where it is installed. The cone viewer accessory serves the other half of the problem — establishing what the detector can actually see from its mounting position, which on a long-range device is not obvious by looking.
Where it fits
Hydrocarbon fire detection in open and semi-open areas: aircraft hangars, fuel loading racks, tank farms, pump and compressor areas, turbine enclosures and chemical process units — the applications where a fire is a pool or a plume rather than a smouldering solid. It is the right instrument where the fuel is a liquid or gas hydrocarbon, and the wrong one where the risk is a paper store or a woodworking shop unless the spacing is designed from the 17 m figure.
Manufacturer reference: Rosemount 965 Flame Detector Product Data Sheet for the detection range table by fuel, spectral response, response time and accessories.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measurement device. The relevant figure is detection distance, which depends on the fuel: 150 ft (45 m) for gasoline and n-heptane, 107 ft (32 m) for JP5, kerosene, diesel, methane and LPG, 100 ft (30 m) for ethanol and methanol, 83 ft (25 m) for polypropylene, and 57 ft (17 m) for paper and wood, at the highest sensitivity setting for a 1 ft2 pan fire |
| Output signal | Analog/HART/RS-485/relays, with HART communication on the 0-20 mA analog current (FSK) for maintenance, configuration changes and asset management. Fault relay normally closed. Universal wiring option for a streamlined ordering process |
| Diagnostics | A flame detector cannot be proven by pressing a button. The FS-975-IR explosion-proof flame simulator projects a flame signature so the installed device can be verified without an open flame; the cone viewer establishes what the detector sees from its mounting position, and the cone of view limiter narrows the field where a flare stack or furnace door sits inside it |
| Pressure range | Not applicable - an optical flame detector with no process connection and no wetted parts |
| Application | Hydrocarbon fire detection in open and semi-open areas: aircraft hangars, fuel loading racks, tank farms, pump and compressor areas, turbine enclosures and chemical process units, where the fire is a pool or a plume rather than a smouldering solid |
| Operating temperature (°C) | Operating -40 to +158 F (-40 to +70 C) |
| Response time | Typically under 5 seconds |
| Spectral response | Four infrared (IR) bands between 4 and 5 micrometres - QuadSense triple infrared (IR3) technology. Discrimination comes from requiring several narrow bands inside the CO2 emission region to agree in ratio, which separates a flame from a bright grey-body source such as a lamp, a welding arc or sunlight, together with the flicker of a flame rather than a steady source |