Ir al contenido principal
Vendido y enviado por Sproh

Medidor de flujo Annubar Rosemount 4051SFA

Número de pieza4051SFAFabricanteEmerson

Opciones de compra

Desde2721,46 US$

Disponibilidad
Consultar disponibilidad Original
Seleccionar opción

Configurable: elija las opciones para construir el número de pieza exacto.

Proveedor independiente

Sproh es un proveedor independiente y no es un distribuidor autorizado ni representante oficial de Rosemount o Emerson.

Resumen

Medidor de flujo por presion diferencial tipo pitot promedio para lineas grandes: 0.8 por ciento de exactitud a 14:1 de rango, baja perdida permanente de presion, liquido, gas o vapor.

Especificaciones principales

Exactitud
Ultra-For-Flow 0.8 percent flow rate accuracy with 14:1 flow turndown, or 28:1 with the universal pressure range option U. Classic 1.25 percent flow rate at 8:1. Because flow relates to differential pressure by a square root, a 14:1 flow turndown is a 196:1 turndown of differential, and 28:1 in flow is roughly 784:1 - which is why the bottom of a DP flow range is where the measurement is weakest
Señal de salida
Flow output by square root extraction from the differential pressure, configurable as volumetric flow, mass flow rate or totalized flow from the display. 4-20 mA with HART and Bluetooth, on the 4051S electronics platform
Diagnósticos
Device and Loop Integrity diagnostics as standard. Enhanced SIS proof testing and logging for safety instrumented service. Process Intelligence with Plugged Impulse Line diagnostic monitors the pressure signal dynamics to detect a partially blocked tap - the characteristic failure of a DP flow meter, which reduces the differential seen and reads as lower flow, so a plant running gently rather than an instrument fault
Rango de presión
Set by the 4051S Coplanar sensor module, its range code and the probe and connection ratings. The Annubar probe is inserted through a single connection into the pipe rather than bolted between flanges
Aplicación
Flow measurement in large line sizes where the cost, weight and installation of a full-bore meter are the problem: water and wastewater mains, air and combustion ducts, steam headers, gas transmission and large process lines. Ordered by fluid type - liquid, gas or steam - because the sizing depends on density and, for gas and steam, on compressibility
Temperatura de operación (°C)
Set by the probe material, the connection and the 4051S sensor module selected; a steam application additionally requires the impulse lines and transmitter arranged so the legs stay filled with condensate and the transmitter sees the correct reference condition
Ver todas las especificaciones