Rosemount 1199 EFW Extended Flanged Seal
Purchase options
From$1,080.97
- Availability
- Call for availability Originalx
Configurable — choose options to build the exact part number.
Independent supplier
Sproh is an independent supplier and is not an authorized distributor or official representative of Rosemount or Emerson.
Overview
Extended flanged diaphragm seal that carries the diaphragm through the nozzle to the tank wall: 1-1/2 in. to 4 in., Class 150 to 2500, for pulp and paper headboxes and slurry vessels.
Key features
- Extended flanged diaphragm seal: the extension carries the diaphragm through the nozzle to the inside tank wall, eliminating the pocket that blinds a normal flanged seal
- Connections 1-1/2 in. to 4 in. (DN 40 to DN 100) in ASME B16.5, EN 1092-1, GOST 33259-15, JIS B2238, HG20615 and HG20592
- Each size carries its own extension diameter (37 mm to 96 mm) because the extension has to pass through the nozzle bore
- Emerson specifies the extension should remain slightly recessed in the nozzle to protect the diaphragm - not standing proud of the wall
- Ratings Class 150 to 2500, or PN 10/16, PN 40, PN 63, PN 100 and PN 160
- Diaphragm in 316L, Alloy C-276, tantalum, duplex 2205 or duplex 2507, with an extension that can be tantalum lined
Key specifications
- Accuracy
- Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and loop accuracy is set by the transmitter, the fill fluid and the capillary run
- Output signal
- Hydraulic: process pressure deflects the diaphragm at the end of the extension and displaces fill fluid to the transmitter, which is ranged for the seal's fill fluid and temperature
- Diagnostics
- Diaphragm in 316L, Alloy C-276, tantalum, duplex 2205 or duplex 2507, with the extension and gasket surface in the same alloy or tantalum lined; solid tantalum is not available on the smaller connections and the tantalum-lined extension requires a gasket surface finish of Ra 125 maximum
- Pressure range
- Flange ratings ASME B16.5 Class 150, 300, 600, 900, 1500 and 2500, or EN 1092-1 / GOST PN 10/16 (DN 100 only), PN 40, PN 63, PN 100 and PN 160, in sizes 1-1/2, 2, 3 and 4 in. (DN 40 to DN 100)
- Variants
- Extension diameters from 1.45 in. (37 mm) to 3.78 in. (96 mm) depending on the connection code, so the extension passes the nozzle bore; 3 in. and 4 in. are offered separately as Schedule 40, Schedule 80 and headbox variants. Extension lengths of 2, 4 and 6 in. are catalogued for the tantalum option, other lengths by factory consultation
- Application
- Pulp and paper stock lines and headboxes, crystallisers and slurry vessels, polymerisation reactors, and any tank where a nozzle-mounted instrument would otherwise look at a stagnant column of process or where agitation could damage a flush diaphragm
An extension long enough to reach the tank wall, and short enough to protect the diaphragm
The Rosemount 1199 EFW is an extended flanged diaphragm seal: a flanged seal whose body carries a cylindrical extension, so the diaphragm reaches through a nozzle and lands at the inside surface of the vessel. It exists for the case where a normal flanged seal would sit at the top of a nozzle with a deep pocket underneath it — and a pocket in a pulp and paper headbox, a crystalliser or a slurry tank fills, blinds the measurement, and has to be rodded out on a schedule.
The extension is dimensioned, not just long
Every size in the EFW model code carries an extension diameter alongside the flange size — 1.45 in (37 mm) through 3.78 in (96 mm) depending on the connection — because the extension has to pass through the nozzle bore. A seal ordered on flange size alone can arrive with an extension that will not enter the nozzle it was bought for. The model list also separates schedules and headbox variants at the same nominal size (3 inch Schedule 40, Schedule 80 and headbox are three different codes with three different diameters), which is exactly the distinction a vessel drawing carries and a purchase order does not.
The instruction that is easy to miss
Emerson's own note on the extension length reads: the extension should remain slightly recessed in the nozzle to protect the diaphragm. That is a more careful statement than "flush with the wall". The intent is that the diaphragm sits at the process boundary so nothing collects in front of it, while the extension stops just short of standing proud, where a paddle, an agitator or a passing lump of pulp would damage it. Getting this wrong in the other direction — extension too short — puts the diaphragm back inside the nozzle and recreates the pocket the seal was bought to eliminate.
Sizes, ratings and standards
Connections run 1½, 2, 3 and 4 inch in ASME B16.5, or DN 40 to DN 100 in EN 1092-1 and GOST 33259-15, JIS B2238, and the Chinese HG20615 and HG20592 standards. Ratings are Class 150, 300, 600, 900, 1500 and 2500, or PN 10/16 (DN 100 only), PN 40, PN 63, PN 100 and PN 160. Extension lengths of 2, 4 and 6 inch are catalogued for the tantalum option, with other lengths by consultation with the factory — which is normal for a part that is dimensioned to a specific vessel.
Materials, and where they pair
Diaphragm options are 316L, Alloy C-276, tantalum, duplex 2205 and duplex 2507, with the extension and gasket surface in 316L, Alloy C-276, duplex, or tantalum-lined — the lining option being how tantalum is offered for the wetted extension without making the whole body from it. The model table flags availability by process connection code, and two constraints are worth reading before a specification is frozen: the solid tantalum diaphragm is not available on the smaller connections, and the tantalum-lined extension requires a gasket surface finish of Ra 125 maximum.
Where it fits
Pulp and paper stock lines and headboxes, crystallisers and slurry vessels, polymerisation reactors, and any tank where a nozzle-mounted instrument would otherwise look at a stagnant column of process. It is also the answer where agitation is present and a flush-mounted diaphragm would be exposed to mechanical damage — the recessed landing is what makes it survive.
Manufacturer reference: Rosemount 1199 Diaphragm Seal Systems Product Data Sheet 00813-0100-4016, EFW extended flanged seal model components and extension length note, and the 1199 quick start guide.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and loop accuracy is set by the transmitter, the fill fluid and the capillary run |
| Output signal | Hydraulic: process pressure deflects the diaphragm at the end of the extension and displaces fill fluid to the transmitter, which is ranged for the seal's fill fluid and temperature |
| Diagnostics | Diaphragm in 316L, Alloy C-276, tantalum, duplex 2205 or duplex 2507, with the extension and gasket surface in the same alloy or tantalum lined; solid tantalum is not available on the smaller connections and the tantalum-lined extension requires a gasket surface finish of Ra 125 maximum |
| Pressure range | Flange ratings ASME B16.5 Class 150, 300, 600, 900, 1500 and 2500, or EN 1092-1 / GOST PN 10/16 (DN 100 only), PN 40, PN 63, PN 100 and PN 160, in sizes 1-1/2, 2, 3 and 4 in. (DN 40 to DN 100) |
| Variants | Extension diameters from 1.45 in. (37 mm) to 3.78 in. (96 mm) depending on the connection code, so the extension passes the nozzle bore; 3 in. and 4 in. are offered separately as Schedule 40, Schedule 80 and headbox variants. Extension lengths of 2, 4 and 6 in. are catalogued for the tantalum option, other lengths by factory consultation |
| Application | Pulp and paper stock lines and headboxes, crystallisers and slurry vessels, polymerisation reactors, and any tank where a nozzle-mounted instrument would otherwise look at a stagnant column of process or where agitation could damage a flush diaphragm |
| Mounting | Bolts to the process flange with the extension passing through the nozzle; Emerson specifies that the extension should remain slightly recessed in the nozzle to protect the diaphragm, which keeps the face at the process boundary without standing proud where an agitator could strike it |
| Operating temperature (°C) | Set by the fill fluid and the diaphragm material; the extension runs through the nozzle and so sees both process and ambient conditions along its length |
Documents
Accessories and related items
Accessories and related items for this product are not available to order on Sproh yet. If the manufacturer lists them, an engineer can source them for you.
Ask an engineer