Sello bridado extendido Rosemount 1199 EFW

Número de pieza1199EFWFabricanteEmerson

Opciones de compra

Desde1080,97 US$

Disponibilidad
Consultar disponibilidad Original
Seleccionar opción

Configurable: elija las opciones para construir el número de pieza exacto.

Proveedor independiente

Sproh es un proveedor independiente y no es un distribuidor autorizado ni representante oficial de Rosemount o Emerson.

Resumen

Sello de diafragma bridado con extensión que lleva el diafragma a través del bocal hasta la pared del tanque: 1-1/2 in. a 4 in., clase 150 a 2500, para headbox de pulpa y papel y recipientes con lodo.

Especificaciones principales

Exactitud
Not a measuring device: the seal transmits process pressure through fill fluid to the transmitter, and loop accuracy is set by the transmitter, the fill fluid and the capillary run
Señal de salida
Hydraulic: process pressure deflects the diaphragm at the end of the extension and displaces fill fluid to the transmitter, which is ranged for the seal's fill fluid and temperature
Diagnósticos
Diaphragm in 316L, Alloy C-276, tantalum, duplex 2205 or duplex 2507, with the extension and gasket surface in the same alloy or tantalum lined; solid tantalum is not available on the smaller connections and the tantalum-lined extension requires a gasket surface finish of Ra 125 maximum
Rango de presión
Flange ratings ASME B16.5 Class 150, 300, 600, 900, 1500 and 2500, or EN 1092-1 / GOST PN 10/16 (DN 100 only), PN 40, PN 63, PN 100 and PN 160, in sizes 1-1/2, 2, 3 and 4 in. (DN 40 to DN 100)
Variantes
Extension diameters from 1.45 in. (37 mm) to 3.78 in. (96 mm) depending on the connection code, so the extension passes the nozzle bore; 3 in. and 4 in. are offered separately as Schedule 40, Schedule 80 and headbox variants. Extension lengths of 2, 4 and 6 in. are catalogued for the tantalum option, other lengths by factory consultation
Aplicación
Pulp and paper stock lines and headboxes, crystallisers and slurry vessels, polymerisation reactors, and any tank where a nozzle-mounted instrument would otherwise look at a stagnant column of process or where agitation could damage a flush diaphragm