Flanged magnetic flow meter for water and wastewater: ½ to 48 in lines, ±0.5% of rate standard or ±0.2% high accuracy, 100 uS/cm minimum conductivity.
Key features
- Flanged electromagnetic flowmeter for water, wastewater and utility applications
- Line sizes ½ to 48 in (15 to 1200 mm); PTFE, polyurethane or neoprene liners
- Standard accuracy ±0.5% of rate from 1 to 39 ft/s; ±0.2% high accuracy option to 12 in
- Requires process conductivity of 100 uS/cm or greater
- 4-20 mA with HART, FOUNDATION Fieldbus or Modbus RS-485, with pulse output
- All-welded coil housing rated IP68; wall mount or integral/remote field mount transmitter
Key specifications
- Accuracy
- Standard system accuracy +/-0.5% of rate from 1 to 39 ft/s (0.3 to 12 m/s) and +/-0.005 ft/s below 1 ft/s; optional high accuracy +/-0.2% of rate from 2.5 to 39 ft/s, which becomes +/-0.50% above 12 in. (300 mm); repeatability +/-0.1% of reading, stability +/-0.1% of rate over six months
- Output signal
- 4-20 mA with HART, FOUNDATION Fieldbus or Modbus RS-485, with pulse output available; response time 20 ms maximum to a step change on the analog output
- Power supply
- Global AC or DC supply depending on the transmitter model; wall mount transmitter is remote only, field mount is available integral or remote
- Diagnostics
- Basic diagnostics include electronics temperature and electrode saturation; DA1 adds coated electrode detection and DA2 adds the full suite, accessible through the LOI, ProLink III or a HART field communicator
- Certifications
- NSF drinking water certification available with the PTFE liner from 0.5 to 36 in. and the polyurethane liner from 4 to 48 in.; flange ratings from ASME Class 150/300 to EN 1092 PN10/16/25 and AWWA C207 Class D/E
- Measurement range
- Line sizes ½ to 48 in (15 to 1200 mm); flow range follows the line size from the low-flow cutoff to 39 ft/s (12 m/s) maximum; process liquid conductivity must be 100 uS/cm or greater
A magnetic flow meter tuned for water and wastewater, not for the lab
The Rosemount 8750W is a flanged electromagnetic flowmeter with a transmitter built around water, wastewater and utility duty: a welded coil housing rated IP68, three liner options, two electrode materials, and a choice of wall-mount or field-mount electronics. It is the workhorse version of the Rosemount magneter — specified where the fluid is conductive, the pipe is full, and the meter has to keep reading for years without attention.
How the measurement works, briefly
A conductive fluid moving through a magnetic field generates a voltage proportional to velocity, and the electrodes pick it up. There is nothing in the flow path to wear or plug — no orifice, no rotor, no moving part — which is why a magneter handles grit, sludge and pulp that would destroy other meters. The condition is conductivity: the process liquid must be at least 100 µS/cm, and a reference electrode specifically requires 100 µS/cm as well. Below that, the meter still reads but the reported values stop being an accurate flow measurement.
Accuracy, and where it depends on size
Standard system accuracy is ±0.5% of rate from 1 to 39 ft/s, with ±0.005 ft/s below 1 ft/s down to the low-flow cutoff. The high-accuracy option reaches ±0.2% of rate from 2.5 to 39 ft/s — but only up to 12 inches; above 300 mm the option is ±0.50% of rate. Repeatability is ±0.1% of reading, stability ±0.1% of rate over six months, and the analog output adds ±4 µA at room temperature on top of the frequency-output accuracy.
Line sizes, liners and electrodes
Line sizes run from ½ in to 48 in (15 to 1200 mm). Liner choice follows the fluid and its temperature: PTFE from -18 to 120 °C, polyurethane from -18 to 60 °C for clean water, and neoprene from -18 to 80 °C for water with chemicals and seawater. Electrodes are 316L stainless steel or nickel alloy 276, with standard, reference and bullet-nose types available. NSF drinking water certification is offered with PTFE liners from 0.5 to 36 in and polyurethane from 4 to 48 in.
Electronics and diagnostics
Both transmitter styles offer 4-20 mA with HART, FOUNDATION Fieldbus or Modbus RS-485, with pulse output alongside, and both come with basic diagnostics as standard plus DA1 and DA2 suites as options. The basic set includes electronics temperature and electrode saturation; DA1 adds coated electrode detection, which is the diagnostic that matters in a plant where the fluid leaves a film — it tells you the reading is drifting because the electrodes are coated, rather than leaving you to discover it at the next calibration.
Installation notes that decide the reading
The sensor needs a full pipe and a straight run: Emerson's sizing guidance exists because a magneter installed downstream of a valve or a bend measures a distorted profile and reports it as flow. Grounding is the other classic failure: grounding rings are the right answer for low-conductivity fluids, cathodic protection or stray currents, and skipping them produces a reading that wanders with the plant's electrical state rather than with the flow.
Where it fits
Municipal and industrial water, wastewater influent and effluent, sludge and slurry lines, and utility water loops — the applications where the fluid is conductive, abrasive or dirty, and where a meter with no moving parts is the only kind that survives.
Manufacturer reference: Rosemount 8750W Magnetic Flowmeter System Product Data Sheet, October 2022, and the 8750W Reference Manual.
Specifications
| Attribute | Value |
|---|---|
| Accuracy | Standard system accuracy +/-0.5% of rate from 1 to 39 ft/s (0.3 to 12 m/s) and +/-0.005 ft/s below 1 ft/s; optional high accuracy +/-0.2% of rate from 2.5 to 39 ft/s, which becomes +/-0.50% above 12 in. (300 mm); repeatability +/-0.1% of reading, stability +/-0.1% of rate over six months |
| Output signal | 4-20 mA with HART, FOUNDATION Fieldbus or Modbus RS-485, with pulse output available; response time 20 ms maximum to a step change on the analog output |
| Power supply | Global AC or DC supply depending on the transmitter model; wall mount transmitter is remote only, field mount is available integral or remote |
| Diagnostics | Basic diagnostics include electronics temperature and electrode saturation; DA1 adds coated electrode detection and DA2 adds the full suite, accessible through the LOI, ProLink III or a HART field communicator |
| Certifications | NSF drinking water certification available with the PTFE liner from 0.5 to 36 in. and the polyurethane liner from 4 to 48 in.; flange ratings from ASME Class 150/300 to EN 1092 PN10/16/25 and AWWA C207 Class D/E |
| Measurement range | Line sizes ½ to 48 in (15 to 1200 mm); flow range follows the line size from the low-flow cutoff to 39 ft/s (12 m/s) maximum; process liquid conductivity must be 100 uS/cm or greater |
| Application | Electromagnetic flow measurement in water, wastewater and utility service: municipal and industrial water, influent and effluent, sludge and slurry lines, and utility water loops |
| Material of construction | Liner in PTFE, polyurethane or neoprene; electrodes in 316L stainless steel or nickel alloy 276 (UNS N10276) with standard, reference or bullet-nose types; flanges in carbon steel or 304/304L SST; all-welded coil housing rated IP68 |
| Operating temperature (°C) | Liner dependent: PTFE -18 to 120 C (0 to 248 F), polyurethane -18 to 60 C (0 to 140 F) for clean water, neoprene -18 to 80 C (0 to 176 F) for water with chemicals and seawater |