Compliance
Leak detection and repair
Summary
LDAR is a loop rather than a survey: find the leak, repair it, prove that the repair held, and leave a record that survives an audit.
A programme, not a campaign
Regulation does not ask for a survey; it asks for a programme — a written procedure saying which components are surveyed, how often, by which method, at what threshold, and what happens to a finding. The component inventory is the foundation: equipment that has never been tagged cannot be scheduled.
The loop then repeats: detect, record, repair, verify, re-survey. Each turn of it produces evidence, and the evidence is what a verifier or an inspector actually reads.
A programme also fixes who is responsible for each step, which is why it is a document rather than a habit.
| Method | How it works | Strength | Limitation |
|---|---|---|---|
| OGI — optical gas imaging | An infrared camera makes a hydrocarbon plume visible | Fast; covers large areas; finds sources nobody listed | Operator-dependent; does not quantify |
| ADM — alternative detection method | An instrument-based survey accepted in place of the prescriptive method | Can be faster or more sensitive; reaches inaccessible assets | Needs approval and evidence it performs at least as well |
| Sniffing — Method 21 | A portable analyser at each component in turn | Quantifies in ppm; the reference other methods are judged against | Slow and labour-intensive |
| Continuous monitoring | Fixed sensors watch an area between campaigns | Catches leaks that start between surveys | Placement and detection limit define what it can see |
Sources and standards
- Regulation (EU) 2024/1787 — LDAR programmes, surveys and repair
- EN 15446 — measurement of fugitive emissions from equipment and piping leaks
- US EPA Method 21 — determination of volatile organic compound leaks