Summary

LDAR is a loop rather than a survey: find the leak, repair it, prove that the repair held, and leave a record that survives an audit.

A programme, not a campaign

Regulation does not ask for a survey; it asks for a programme — a written procedure saying which components are surveyed, how often, by which method, at what threshold, and what happens to a finding. The component inventory is the foundation: equipment that has never been tagged cannot be scheduled.

The loop then repeats: detect, record, repair, verify, re-survey. Each turn of it produces evidence, and the evidence is what a verifier or an inspector actually reads.

A programme also fixes who is responsible for each step, which is why it is a document rather than a habit.

Survey methods
MethodHow it worksStrengthLimitation
OGI — optical gas imagingAn infrared camera makes a hydrocarbon plume visibleFast; covers large areas; finds sources nobody listedOperator-dependent; does not quantify
ADM — alternative detection methodAn instrument-based survey accepted in place of the prescriptive methodCan be faster or more sensitive; reaches inaccessible assetsNeeds approval and evidence it performs at least as well
Sniffing — Method 21A portable analyser at each component in turnQuantifies in ppm; the reference other methods are judged againstSlow and labour-intensive
Continuous monitoringFixed sensors watch an area between campaignsCatches leaks that start between surveysPlacement and detection limit define what it can see
Method names differ between jurisdictions. The Regulation leaves room for advanced detection technologies where a competent authority approves them.

Sources and standards

  1. Regulation (EU) 2024/1787 — LDAR programmes, surveys and repair
  2. EN 15446 — measurement of fugitive emissions from equipment and piping leaks
  3. US EPA Method 21 — determination of volatile organic compound leaks

Continue reading