Resources
Standards and guidance
A short list of documents that recur in gas-detection and emissions work, described by what they cover rather than by number alone. A map, not a substitute for reading them.
Reference material
Standards are cited constantly and read rarely. The table lists only documents whose scope can be stated with confidence, one line each; where no single standard applies, the page says so rather than approximating a number.
| Standard | What it covers |
|---|---|
| IEC 60079-29-1 | Performance requirements for flammable-gas detectors: the metrological baseline for testing. |
| IEC 60079-29-2 | Selection, installation, use and maintenance of detectors for flammable gases and oxygen. |
| IEC 60079-29-3 | Functional safety of fixed gas detection systems, under IEC 61508 and IEC 61511. |
| IEC 60079-29-4 | Performance requirements for open-path detectors, which integrate concentration along a path. |
| IEC 60079-10-1 | Classification of hazardous areas with explosive gas atmospheres: the zone sets the equipment. |
| ISO 14064-1 | Greenhouse gas quantification and reporting at organisation level: the inventory frame. |
| EPA Method 21 | Volatile organic compound leaks from process equipment, measured with a portable analyser. |
| OGMP 2.0 | A reporting framework, not a standard: reporting levels, measurement-based at the top. |
How to use a standard
Read the scope first: a performance standard says how a detector is tested, not where it belongs. Then check the edition and the national adoption, because a standard quoted from memory is a common source of a wrong requirement.