Skip to content
MetIQGas intelligence

Technology

Methane monitoring

Methane is colourless, odourless and lighter than air — which is exactly the combination that makes periodic walkover inspection a poor fit for large sites.

Methane has no odour of its own: the smell in domestic gas is an added mercaptan, and none of it is present in a transmission network or a compressor station. A leak is therefore invisible until it is either detected by an instrument or reported by someone.

Periodic inspection samples time as well as space. A survey that visits a site four times a year observes roughly 0.5% of the hours in that year, so a leak that starts between visits is found late or not at all — the argument behind the shift to continuous measurement in the EU methane regulation.

What continuous optical monitoring changes

  • A leak is timed, not just located: the record shows when it started and how it developed.
  • Emissions can be integrated over a period, which is what a quantified inventory needs.
  • Recurring events at the same asset become visible as a pattern rather than as unrelated findings.
  • Verification of a repair is immediate: the measurement continues after the work is done.

Where the difficulty actually is

Detection is the easy half. The hard half is attribution — deciding whether a rise in concentration is a leak from the asset under monitoring, a neighbouring source, or a change in wind and atmospheric stability. That is a modelling problem, and it is why quantification and dispersion are treated as their own topics in this site.

Continue reading