Skip to content
MetIQGas intelligence

Field services

Sensor layout

A layout is a set of defensible decisions, not a spacing rule. Each position has to be explained by the release it watches and the wind that carries it.

A spacing figure copied from another site is not a design. The same asset in a different enclosure, wind and access regime needs different positions, and a different argument.

Layout is iterative: candidate positions are proposed, tested against how gas would travel, then reconciled with what the site will accept.

How a layout is decided

  1. Fix the objective

    State what the layout must do: detect at the asset, cover a boundary, or feed a model. Each gives a different criterion.

  2. Place from the release

    Start from release points and plume paths, not a grid, then test positions against the wind sectors that matter.

  3. Test the coverage

    Check what the positions observe together, and where a single instrument failure would leave the site blind.

  4. Reconcile with the site

    Adjust for mounting surfaces, heights, cable routes, access and zoning without dropping the coverage argument.

  5. Record the reasoning

    Issue positions, heights and orientations with a statement of what is not observed.

What the layout delivers

  • Positions and mounting heights on a plot plan.
  • Orientation and field of view for each position.
  • Cable and network routes for those positions.
  • A coverage statement with its limits.

Continue reading