Resources
Glossary
The vocabulary of gas monitoring is small but used unevenly: the same word can name a measurement principle, a programme or a regulatory category. These are the definitions this site uses.
Reference material
Terms are ordered roughly as a project meets them: the principles that produce a number, the performance vocabulary that qualifies it, the programmes that act on it, and the modelling terms that turn a concentration into a mass rate.
Where an abbreviation is used inconsistently across the industry, the definition says so. A document that defines its terms is easier to audit than one that assumes them.
Measurement, performance and modelling terms
- TDLAS — tunable diode laser absorption spectroscopy
- A laser is tuned across one absorption line of the target gas, and the depth of the absorption gives concentration over a known path length. Selective against other hydrocarbons, with no consumable in the optical path, but it needs a stable, clean optical path to stay honest.
- NDIR — non-dispersive infrared
- A broadband infrared source and a gas-specific band-pass filter measure absorption in one band. Common for methane and carbon dioxide; simpler and cheaper than a laser, and correspondingly less selective.
- PID — photoionisation detector
- Ultraviolet light ionises molecules in the sample and the resulting current is read as concentration. Sensitive to many volatile organic compounds, but not selective between them without a separation step.
- Pellistor — catalytic bead
- A coated bead is heated, and any combustible gas that burns on it raises its temperature; the change in resistance is the signal. It needs oxygen to work and is poisoned by silicones and some sulphur compounds.
- LOD — limit of detection
- The lowest concentration distinguishable from the noise of the instrument itself at a stated confidence, conventionally three times the standard deviation of the blank. Not the same as the lowest concentration the display can show.
- LDAR — leak detection and repair
- A programme of periodic surveys, tagging of leaking components, repair within a deadline and re-verification. It is normally defined by regulation, so intervals and methods differ between jurisdictions.
- OGI — optical gas imaging
- An infrared camera tuned to an absorption band renders a plume as visible contrast against the background. Strong at finding and roughly locating a leak; it does not measure concentration or mass rate.
- ADM — atmospheric dispersion model
- A model that computes how a release is carried and diluted by wind and turbulence. The abbreviation is used loosely in the literature, so a document that uses it should say which model it means.
- ppm and ppm·m
- ppm is parts per million by volume, one part in a million. ppm·m is a path-integrated concentration: ppm multiplied by the path length in metres, as reported by open-path instruments and convertible to a column density.
- Gaussian plume
- The classical steady-state dispersion solution: a continuous point source in a uniform wind gives a concentration field that is Gaussian across the wind and in the vertical. Fast and transparent, but it assumes conditions a real site rarely holds exactly.
- Stability class
- A Pasquill–Gifford category from A to F describing how much turbulence the atmosphere is producing. A is very unstable and disperses quickly; F is very stable and lets a plume travel further. It is an input to a model, not a measurement.
- Mass rate
- The mass of gas released per unit time, in kilograms per hour for instance. It is derived from concentration, geometry and meteorology rather than read from a point sensor, and it should be reported with an uncertainty interval.
- Emission factor
- A ratio used to estimate emissions from an activity level, such as kilograms of methane per kilometre of pipeline. A statistical average: appropriate for an inventory, unsuitable for judging one asset on one day.
- OGMP
- The Oil and Gas Methane Partnership, a UNEP-facilitated reporting framework. OGMP 2.0 sets out reporting levels, and the higher ones require measurement-based data rather than emission factors alone.
- ATEX zone
- A classification of hazardous areas under EU law: zones 0, 1 and 2 for explosive gas atmospheres, and 20, 21 and 22 for dust. The zone decides what may be installed in it, not what has to be measured there.