The answers separate what is established from what depends on the site. Where an answer is that it depends, it says on what.

Reference material

These are the questions that come up in almost every first conversation, answered here rather than in a brochure because several of them have no single correct answer. A page that pretends otherwise would be shorter and less useful.

Questions and answers

Is continuous monitoring a legal requirement?

It depends on the jurisdiction and on the activity. The EU methane regulation places monitoring and reporting obligations on operators within its scope, and some national regimes require leak detection programmes; many do not yet require continuous measurement. The law that applies to the site decides, not a general rule.

Does MetIQ publish detection thresholds or accuracy figures?

Not on this site. Performance depends on the gas, the path length, the environment and the maintenance regime, so a single figure would mislead. Where figures exist, they belong in the documentation for a specific instrument and a specific deployment.

What is the difference between detection and quantification?

Detection answers whether there is a release. Quantification estimates how much mass leaves per unit time, which needs meteorology and a dispersion model. Detection is a measurement; quantification is a model informed by measurements, and it carries a wider uncertainty.

How often does a sensor need calibrating?

The interval depends on the sensing principle, the environment and the manufacturer instructions, and it is normally fixed in the site procedure. A dusty or corrosive site needs shorter intervals than a clean one. What matters is that the interval is written down and the records are kept.

Can one instrument cover a whole site?

Generally not. A point detector measures at a point, and an open-path instrument averages along a line. Covering an area is a design exercise in geometry, wind and leak likelihood, which is why sensor placement is treated as a problem in its own right.

What weather data does a system need?

At least wind speed and direction at a height representative of the plume, plus temperature and pressure. A stability indicator improves attribution. Without wind data, a rising concentration cannot be attributed to a source.

Does continuous monitoring replace LDAR surveys?

Sometimes, where the regulator accepts a measurement-based alternative, and rarely without conditions: a detection limit, a response time and an audit trail. In many regimes LDAR remains the baseline and continuous monitoring supplements it.

What does ppm·m mean?

It is a path-integrated concentration: parts per million multiplied by the optical path length in metres. Open-path instruments report it because they cannot know how the gas is distributed along the path. Dividing by the path length gives an average concentration.

Can the same instrument monitor hydrogen and methane?

Rarely. Methane has strong absorption bands in the near and mid infrared and hydrogen does not, so optical methane instruments are generally unsuitable for hydrogen. Catalytic and electrochemical sensors are common instead, and placement changes because hydrogen rises.

What happens if the network goes down?

A well-designed node buffers locally and forwards when the link returns, marking the gap rather than interpolating across it. A record with an honest gap is usable; a record with invented values is not.

How long should monitoring data be kept?

Long enough to cover the reporting cycle and any audit of it, which is set by the regime the site reports under. Retention is a legal and contractual question, not a technical default.

Does MetIQ certify a site as compliant?

No. Conformity assessment is carried out by accredited bodies against a defined standard, and compliance is a matter for the operator and the regulator. MetIQ supplies measurement; it does not issue certificates.